Why the network that runs the building deserves the same engineering as the network that runs the workloads
Ask a data center architect to describe the network and you will hear about the fabric. Spine and leaf. 400G and 800G optics. Lossless Ethernet for GPU clusters. That conversation matters, and Cisco has invested heavily in it. It also covers only part of the data center network infrastructure in a modern facility.
Walk the building and count the other endpoints. Lighting in every aisle and corridor. Badge readers and cameras at every entry point and loading dock. Temperature and humidity sensors in electrical rooms, battery rooms, and support spaces. Each one needs power and a data connection, and in most facilities they still get both from a separate electrical design, separate contractors, and a separate set of controls the network team never sees.
That second layer is where Cisco Catalyst switching and MHT’s Power over Ethernet (PoE) technology come together.
Three Networks Under One Roof
A data center typically runs more than one network, and each has a different job.
The production fabric carries the workloads. In Cisco environments, that means Nexus 9000 Series switches, increasingly built on Cisco Silicon One and operated through Cisco Nexus One. Cisco describes Nexus One as a single architecture across silicon, systems, and software, managed through Nexus Dashboard, with Nexus Hyperfabric adding cloud-managed operations across the full lifecycle of the fabric.
Alongside it sits the out-of-band management network, a physically separate path that keeps engineers connected to the infrastructure when the production network is down.
Then there is the facility network. Cisco refers to the operational side of the data center as its gray space: generators and substations, battery systems, switchgear, cooling, building management, and security systems. Cisco is direct about the stakes, noting that a cyberattack or an unintended configuration change in that environment can disrupt power or cooling and shut down the entire facility.
Lighting, sensors, access control, and cameras all live in this third network. They rarely get the attention the fabric gets, but they share the same building and the same consequences when something goes wrong.
Where Cisco Catalyst Fits
Nexus switches are engineered to move workload traffic at enormous scale. The facility layer has a different requirement: it needs power at the port. That is the job of Cisco Catalyst access switching.
The Cisco Catalyst 9300 Series delivers up to 90 watts per port through Cisco UPOE+, based on the IEEE 802.3bt standard. A single Catalyst 9300X can provide up to 48 ports of 90W UPOE+, and an eight-member stack scales to 384. Cisco StackPower pools power supplies across the stack, so one switch’s supply can back up another’s.
Two Catalyst features matter more in a data center than almost anywhere else. Perpetual PoE keeps power flowing to connected devices while the switch reloads, and Cisco names PoE-powered lights as the reason the feature exists. Fast PoE restores power to endpoints after a power event without waiting for the switch operating system to finish booting.
In practice, a scheduled firmware upgrade on a Catalyst switch does not plunge a data hall into darkness while a technician is working between racks. For operations teams who already plan every maintenance window around risk, that detail decides whether PoE lighting is merely acceptable or clearly preferable.
What MHT’s Inspextor Adds at the Port
A PoE port delivers power and data. Inspextor turns that port into controlled building infrastructure.
Inspextor is MHT’s PoE hardware platform, designed to run on enterprise PoE networks including Cisco switches delivering 90W UPOE+. The Core Node handles lighting control and general device integration. Node 90 supports a wider mix of low-voltage devices from a single node. SuperNode adds programmable analog inputs and high-density lighting control for larger, multi-zone spaces. PoE splitters let one switch port feed several fixtures where loads are light, which stretches a switch’s port count across long aisles.
Emergency lighting is often where low-voltage designs run into code questions. MHT’s patented MHTi-EM100 emergency driver installs inside compatible PoE fixtures and provides 8 watts of emergency illumination for a minimum of 90 minutes. It is UL 924 compliant and requires no separate line-voltage emergency circuit.
Above the hardware, aida™, the intelligent building management platform developed by Building AI Solutions, uses the power and connectivity data Inspextor supplies to deliver centralized control, scheduling, occupancy response, and energy tracking. In a data hall, that can mean aisle lighting that responds to technician presence rather than running around the clock, along with fixture-level power data that facilities teams can actually report on.
Inspextor is also device agnostic. Sensors, access control hardware, and other compatible low-voltage devices can join the same platform, so the facility layer ends up with one control environment in place of a collection of proprietary systems.
Segmentation Is Part of the Design
Putting building systems on the network raises a fair question: should lighting controllers share infrastructure with anything that matters? Cisco’s answer for the gray space is segmentation. Its guidance recommends separating facility systems from production and out-of-band networks, restricting communications to approved BMS, DCIM, and facility flows, and keeping physical security systems apart from both enterprise and facility-control networks.
Catalyst switching supports that model directly. With the appropriate licensing, the Catalyst 9300 Series supports VRF segmentation, Cisco TrustSec group-based policy, and identity-based access through Cisco Identity Services Engine. An Inspextor deployment can live in its own segment, reporting to aida and the facilities team, with no path into the production fabric. Hardwired PoE controls also avoid the exposure that comes with wireless lighting protocols, which is one reason MHT positions PoE as the more secure choice for critical facilities.
Planning the Facility Layer
A few practical considerations come up on nearly every data center PoE project.
Power budgeting comes first. Every Catalyst model has a PoE budget that depends on its power supply configuration, so the fixture count, sensor load, and any 90W devices on each switch should be mapped before switches are ordered.
Distance comes next. A standard Ethernet channel runs up to 100 meters, which shapes where facility switches sit. Large data halls often need switch locations along the perimeter or in intermediate closets to reach the far end of long aisles.
Ownership is the third. The network team knows Catalyst, and the facilities team knows the lighting and life-safety requirements. Projects that go smoothly assign ownership and maintenance windows for the facility switches before construction starts, and they configure Perpetual PoE and Fast PoE on lighting ports as part of the standard build.
One Infrastructure, Two Jobs
The fabric will keep getting the headlines, and it should. AI workloads are pushing data center networking forward faster than at any point in recent memory. A data center is still a building, though, and the systems that light it, secure it, and monitor its environment need a network too.
Cisco Nexus carries the workloads. Cisco Catalyst powers and connects the facility. MHT’s Inspextor hardware turns those Catalyst ports into lighting, sensing, and control, with aida providing the visibility on top. Planned together, they give operators data center network infrastructure that covers the whole building, from the spine switches to the light over the loading dock.
To talk through PoE for a data center project, contact the MHT team or explore our data center solutions.
Related reading: Mission Critical Data Center Infrastructure and how Fault Managed Power and PoE come together with Cisco and Panduit.