PoE Power Sourcing Equipment (PSE)

PoE Power Sourcing Equipment, commonly abbreviated as PSE, is the equipment that supplies Power over Ethernet to a connected device. In a PoE network, the PSE sends DC electrical power over Ethernet cabling while the same connection can also carry network data.

PoE switches and PoE injectors are common examples of Power Sourcing Equipment. The device receiving the power is known as a Powered Device, or PD. Together, the PSE and PD form the two ends of a PoE connection.

What Does PSE Mean in PoE?

PSE stands for Power Sourcing Equipment. Its role is to provide electrical power to compatible devices through twisted-pair Ethernet cabling.

The PSE is located on the power-supplying side of the connection. A camera, wireless access point, sensor, controller or other device receiving that power is located at the other end.

This distinction is important because PoE specifications often list different power levels for the PSE and PD. The amount of power supplied by the PSE is higher than the maximum amount guaranteed to be available at the powered device because some power can be lost through the Ethernet channel.

Our guide to how much power PoE can deliver explains these power levels in more detail.

Is a PoE Switch a PSE?

Yes. A PoE switch is one of the most common forms of Power Sourcing Equipment.

The switch connects devices to the Ethernet network while also supplying PoE through compatible ports. This allows a single Ethernet connection to provide network communications and electrical power to a device.

A multiport PoE switch can function as the PSE for many devices at the same time. Each port must support the required PoE power level, while the switch must also have enough total PoE power budget to support all connected devices.

Is a PoE Injector Also a PSE?

Yes. A PoE injector is another type of PSE.

An injector is typically used when the existing network switch does not provide PoE. The injector is installed between the non-PoE network connection and the powered device. It adds electrical power to the Ethernet connection so that compatible equipment can receive both data and power.

A PoE switch and PoE injector therefore perform the same basic PSE function—supplying PoE—but they do it through different equipment configurations.

How Does a PSE Know When to Supply Power?

Standards-based PoE is designed so that the PSE does not simply apply normal PoE power to anything plugged into an Ethernet port.

Before supplying operating power, the PSE performs a detection process to determine whether a compatible Powered Device is connected. Once a valid device is detected, the PSE and PD can establish the appropriate power relationship based on the PoE standard and capabilities of the equipment.

This process helps make PoE safe for network infrastructure that may contain both powered and non-powered Ethernet devices.

How Much Power Can a PSE Provide?

The amount of power depends on the PoE standard supported by the PSE.

IEEE PoE standards have increased the available power substantially over time. Earlier PoE equipment provided relatively modest amounts of power, while newer IEEE 802.3bt equipment can support much higher-power devices.

At the upper end, Type 4 PoE can provide up to 90 watts at the PSE. The maximum power available at the PD is lower because the standard accounts for power losses through the Ethernet channel.

This difference between PSE output and PD input is important when selecting equipment. A device’s power requirements need to be compared with the power available at the device, not simply the maximum output advertised for the PSE.

What Is the Difference Between PSE Power and a PoE Power Budget?

PSE power can refer to how much power a port is capable of providing, while the PoE power budget describes the total amount of PoE power that equipment such as a switch can distribute across its powered ports.

For example, a switch may contain ports capable of high-power PoE without having enough total power capacity to operate every port at maximum output simultaneously.

Designers therefore need to consider both per-port capability and total PSE capacity when selecting PoE equipment.

What Happens to a PSE During a Power Outage?

Power Sourcing Equipment needs electrical power of its own. If a PoE switch or injector loses its incoming electrical supply, it can no longer provide PoE to connected devices.

This is why backup power is often considered at the PSE level. A UPS can potentially keep a PoE switch operating, which in turn can keep multiple connected devices powered from a centralized location.

Our resource on what happens to PoE during a power outage explains backup power and PoE operation during an outage in more detail.

What Is the Difference Between a PSE and a PD?

The distinction is straightforward:

PSE supplies the power. PD receives the power.

A PoE switch or injector is typically the PSE. A camera, access point, sensor, controller or other PoE-powered device can be the PD.

The two sides work together to establish a compatible PoE connection and determine how power will be delivered.

Why Is PSE Important in a PoE System?

The PSE determines where network-delivered power originates, how much power is available per connection and how much total PoE capacity can be distributed to connected equipment.

In a small installation, the PSE might be a single injector powering one device. In a commercial building, multiple PoE switches can serve as centralized power sources for lighting controllers, PoE sensors and other connected equipment throughout the facility.

Understanding Power Sourcing Equipment makes many other PoE concepts easier to understand. When specifications refer to power at the PSE, they mean power at the source. When they refer to power at the PD, they mean the power available at the receiving end of the Ethernet connection.